Technical specifications
| Solar array | ≈5.4 kWp (10 x 540 Wp modules, DCR option) |
|---|---|
| Inverter | 5 kW hybrid (1-phase) or 5–6 kW (3-phase) |
| Battery | 5.12 kWh or 10.24 kWh lithium LFP, 51.2 V |
| Backup switchover | <10–20 ms |
| Expected generation | ≈20–25 units/day |
| Roof area required | ≈450–500 sq ft shadow-free |
| Mounting | GI or aluminium, elevated option |
| Protection | ACDB, DCDB, SPDs, earthing, lightning arrester |
| Monitoring | App with solar, battery and load data |
| Suitable consumption | ≈500–750 units/month |
Prices, subsidies and tariffs change from time to time. Call us or fill the form for the latest figures.
Who is it for?
Larger homes using 500–750 units a month, households in areas with daily load-shedding, work-from-home professionals, and families replacing a conventional inverter and battery with a solar-charged system.
Key benefits
- Two jobs, one system: lower bills and backup without a separate home UPS.
- Silent and clean: no generator noise or fumes.
- Smart control: battery charges from solar first, and the grid tops it up only if needed.
- Grows with you: add another LFP module later.
Technical specifications
| Specification | Typical value |
|---|---|
| Solar array | ≈5.4 kWp (10 x 540 Wp modules, DCR option) |
| Inverter | 5 kW hybrid (1-phase) or 5–6 kW (3-phase) |
| Battery | 5.12 kWh or 10.24 kWh lithium LFP, 51.2 V |
| Backup switchover | <10–20 ms |
| Expected generation | ≈20–25 units/day |
| Roof area required | ≈450–500 sq ft shadow-free |
| Mounting | GI or aluminium, elevated option |
| Protection | ACDB, DCDB, SPDs, earthing, lightning arrester |
| Monitoring | App with solar, battery and load data |
| Suitable consumption | ≈500–750 units/month |
Installation & warranty
We study your essential loads, wire them to a dedicated backup panel and configure the hybrid inverter for self-use or backup priority. Installation usually takes 2–4 days, followed by DISCOM net-meter commissioning. Typical warranties: 25 years linear on panels, 5–10 years on inverter and battery. Plan storage with the battery backup calculator.
Key takeaways
- 5.4 kWp solar + hybrid inverter + 5–10 kWh LFP
- About 20–25 units a day and backup in outages
- Indicative ₹4,00,000–6,50,000 incl. GST
- Subsidy (if eligible) covers solar only, not the battery
Want savings and backup together? get a free quote for a hybrid system sized to your home.
Frequently asked questions
How much backup will I get from a 5 kW hybrid system?
With a 5.12 kWh LFP battery, an 800 W essential load runs for about 5–6 hours. With 10.24 kWh, the same load runs for about 11 hours. Solar recharges the battery during the day.
Can I run an AC on a hybrid solar system?
Yes, a 1–1.5 ton inverter AC can run on solar during the day. On battery alone it drains storage quickly, so most homes keep ACs off the backup circuit.
Does the subsidy apply to a hybrid system?
The central subsidy is linked to grid-connected solar capacity with DCR modules (capped at ₹78,000). The battery is not subsidised. Confirm eligibility with your DISCOM and the portal.
How many units does a 5 kW system generate?
About 20–25 units a day, or roughly 6,000–7,500 units a year in most Indian locations.