Why it matters
Pre-monsoon and monsoon thunderstorms bring frequent lightning across eastern UP, Bihar, Odisha, Jharkhand and other regions. A rooftop array is often the highest metal object on a building. A properly placed arrester creates a protection zone over the array and greatly reduces the risk of panel, inverter and building damage.
How it works in India
- Type: conventional Franklin rod or ESE (early streamer emission) arrester, as per design.
- Placement: above the highest panel, so the whole array falls within its protection angle or radius.
- Down-conductor: copper or GI strip routed away from DC cables.
- Earthing: a separate, dedicated earth pit.
- Design reference: IS/IEC 62305 lightning protection standard.
| Protection layer | Handles |
|---|---|
| Lightning arrester | Direct strikes |
| SPDs in DCDB / ACDB | Induced surges on cables |
| Earthing system | Safe dissipation of current |
Ensure the arrester’s shadow does not fall on panels; mount it on the north side where possible. Inspect connections yearly before the monsoon. Read our solar maintenance guide and see residential solar.
Send your electricity bill or a roof photo on WhatsApp and we will suggest the right system and price.
Frequently asked questions
Is a lightning arrester compulsory for rooftop solar?
It is part of most MNRE and state scheme technical specifications and is strongly recommended, especially on tall or isolated buildings.
Does a lightning arrester replace surge protection devices?
No. The arrester handles direct strikes; SPDs in the DCDB and ACDB protect electronics from induced surges. Both are needed.