For Business / Bulk

Three-Phase Commercial On-Grid Inverter 20–125 kW

High-power three-phase string inverters for factories, warehouses, institutions and EPC projects from 20 kW to multi-MW.

  • Up to ~99% efficiency for maximum yield
  • Multiple MPPTs for complex industrial roofs
  • Smart string-level monitoring
  • Zero-export and power-factor control
  • IP66 for dusty, humid industrial sites
  • SCADA and EMS integration
PriceOn request. B2B project pricing depends on rating, quantity and plant design; ex-GST.
SKU: SEMS-INV-CI20-125
Genuine, warranty-backed Pan-India dispatch Installation available

Technical specifications

Power ratings20, 25, 30, 40, 50, 60, 80, 100, 110, 125 kW
MPPT trackers2–10 depending on model
Max DC voltage1100 V (up to 60 kW) / 1100–1500 V (higher ratings)
Max efficiency≈98.5–99.0%
Euro efficiency≈98.0–98.5%
Grid connection415 V, 3-phase, 50 Hz (LV); HT via transformer
ProtectionsAnti-islanding, Type II DC/AC SPD, AFCI (optional), string monitoring, PID recovery (optional)
EnclosureIP66, smart fan cooling
CommunicationRS485, Wi-Fi/4G/Ethernet, Modbus TCP
Export controlZero / limited export with meter or plant controller
StandardsCompliant with CEA grid-connectivity regulations; BIS (IS 16221, IS 16169)
Quick answer: Three-phase commercial on-grid inverters from 20 to 125 kW are the backbone of rooftop and ground-mount C&I solar plants. They offer multiple MPPTs, about 98.5–99% efficiency, string-level monitoring and zero-export control. Several units together scale a plant from 50 kW to multiple MW with less downtime risk than a single central inverter.

Who is it for?

Factories, MSMEs, warehouses, hospitals, colleges, malls and EPC contractors building 50–500 kW C&I plants under net metering, gross metering or open access (≥100 kW under the Green Energy Open Access Rules 2022).

Key benefits

  • Modular reliability: one inverter fault takes only a fraction of the plant offline.
  • Grid compliance: reactive power, power factor and ramp control to meet CEA and DISCOM requirements.
  • Lower O&M: string current monitoring flags soiled or faulty strings early.
  • Integration: works with DG synchronisation controllers and our energy management system.

Technical specifications

Specification Typical value
Power ratings 20, 25, 30, 40, 50, 60, 80, 100, 110, 125 kW
MPPT trackers 2–10 depending on model
Max DC voltage 1100 V (up to 60 kW) / 1100–1500 V (higher ratings)
Max efficiency ≈98.5–99.0%
Euro efficiency ≈98.0–98.5%
Grid connection 415 V, 3-phase, 50 Hz (LV); HT via transformer
Protections Anti-islanding, Type II DC/AC SPD, AFCI (optional), string monitoring, PID recovery (optional)
Enclosure IP66, smart fan cooling
Communication RS485, Wi-Fi/4G/Ethernet, Modbus TCP
Export control Zero / limited export with meter or plant controller
Standards Compliant with CEA grid-connectivity regulations; BIS (IS 16221, IS 16169)

Installation & warranty

We size inverters through yield simulation, select DC/AC ratios and plan cable routes to keep DC losses under about 1.5%. Inverters are wall- or rack-mounted under a canopy with clearance for airflow. DG-sync controllers prevent reverse power into diesel generators. Standard warranty is 5–10 years, extendable, with AMC options.

Key takeaways

  • 20–125 kW three-phase, ~98.5–99% efficiency
  • Multiple MPPTs and string monitoring for C&I roofs
  • Zero-export and DG synchronisation supported
  • Price on request for B2B projects

Building a C&I plant or EPC project? get a free quote for inverter selection and a yield simulation. Installers can apply to our dealer program.

Frequently asked questions

Why use string inverters instead of a central inverter for C&I?

Multiple string inverters give more MPPTs, easier maintenance and less downtime because one fault does not stop the whole plant. Central inverters are mostly used in utility-scale ground-mount plants.

Can the inverter limit export to the grid?

Yes. With a smart meter or power controller it can run in zero-export or limited-export mode, which is useful where net metering is capped or not allowed.

What DC/AC ratio is used in C&I plants?

Typically 1.15–1.35 depending on location, tilt and DISCOM rules. Our engineers model this in a yield simulation.

Do these inverters support open access projects?

Yes. They can be used in open access, net-metered and gross-metered plants, with SCADA or plant-controller integration on request.

You may also need

HomeBusiness

Hybrid Solar Inverter 3–10 kW

Hybrid inverters that combine on-grid export with battery backup, so your home or office keeps running during load-shedding.

Indicative ₹55,000–2,50,000 depending on rating, phase and battery voltage, ex-GST (5% GST applies); battery…

सूर्य की शक्ति, भारत की प्रगति

Need a complete system, not just a product?

Our engineers will design a matched system — panels, inverter, battery, structure and protection — and install it end-to-end.