Technical specifications
| Power ratings | 20, 25, 30, 40, 50, 60, 80, 100, 110, 125 kW |
|---|---|
| MPPT trackers | 2–10 depending on model |
| Max DC voltage | 1100 V (up to 60 kW) / 1100–1500 V (higher ratings) |
| Max efficiency | ≈98.5–99.0% |
| Euro efficiency | ≈98.0–98.5% |
| Grid connection | 415 V, 3-phase, 50 Hz (LV); HT via transformer |
| Protections | Anti-islanding, Type II DC/AC SPD, AFCI (optional), string monitoring, PID recovery (optional) |
| Enclosure | IP66, smart fan cooling |
| Communication | RS485, Wi-Fi/4G/Ethernet, Modbus TCP |
| Export control | Zero / limited export with meter or plant controller |
| Standards | Compliant with CEA grid-connectivity regulations; BIS (IS 16221, IS 16169) |
Who is it for?
Factories, MSMEs, warehouses, hospitals, colleges, malls and EPC contractors building 50–500 kW C&I plants under net metering, gross metering or open access (≥100 kW under the Green Energy Open Access Rules 2022).
Key benefits
- Modular reliability: one inverter fault takes only a fraction of the plant offline.
- Grid compliance: reactive power, power factor and ramp control to meet CEA and DISCOM requirements.
- Lower O&M: string current monitoring flags soiled or faulty strings early.
- Integration: works with DG synchronisation controllers and our energy management system.
Technical specifications
| Specification | Typical value |
|---|---|
| Power ratings | 20, 25, 30, 40, 50, 60, 80, 100, 110, 125 kW |
| MPPT trackers | 2–10 depending on model |
| Max DC voltage | 1100 V (up to 60 kW) / 1100–1500 V (higher ratings) |
| Max efficiency | ≈98.5–99.0% |
| Euro efficiency | ≈98.0–98.5% |
| Grid connection | 415 V, 3-phase, 50 Hz (LV); HT via transformer |
| Protections | Anti-islanding, Type II DC/AC SPD, AFCI (optional), string monitoring, PID recovery (optional) |
| Enclosure | IP66, smart fan cooling |
| Communication | RS485, Wi-Fi/4G/Ethernet, Modbus TCP |
| Export control | Zero / limited export with meter or plant controller |
| Standards | Compliant with CEA grid-connectivity regulations; BIS (IS 16221, IS 16169) |
Installation & warranty
We size inverters through yield simulation, select DC/AC ratios and plan cable routes to keep DC losses under about 1.5%. Inverters are wall- or rack-mounted under a canopy with clearance for airflow. DG-sync controllers prevent reverse power into diesel generators. Standard warranty is 5–10 years, extendable, with AMC options.
Key takeaways
- 20–125 kW three-phase, ~98.5–99% efficiency
- Multiple MPPTs and string monitoring for C&I roofs
- Zero-export and DG synchronisation supported
- Price on request for B2B projects
Building a C&I plant or EPC project? get a free quote for inverter selection and a yield simulation. Installers can apply to our dealer program.
Frequently asked questions
Why use string inverters instead of a central inverter for C&I?
Multiple string inverters give more MPPTs, easier maintenance and less downtime because one fault does not stop the whole plant. Central inverters are mostly used in utility-scale ground-mount plants.
Can the inverter limit export to the grid?
Yes. With a smart meter or power controller it can run in zero-export or limited-export mode, which is useful where net metering is capped or not allowed.
What DC/AC ratio is used in C&I plants?
Typically 1.15–1.35 depending on location, tilt and DISCOM rules. Our engineers model this in a yield simulation.
Do these inverters support open access projects?
Yes. They can be used in open access, net-metered and gross-metered plants, with SCADA or plant-controller integration on request.