PM Surya Ghar: get up to ₹78,000 subsidy on home rooftop solar — scheme open till 31 March 2027 · Check your subsidy →
Solar-powered water pumps with panels in a farm Subsidy eligible
For HomesFor Business / Bulk

5 HP Solar Water Pump (PM-KUSUM)

A 5 HP solar irrigation pump set with DCR panels, controller and structure, for farmers applying under PM-KUSUM or buying direct.

  • Zero diesel and zero electricity bill for irrigation
  • DCR solar array for PM-KUSUM eligibility
  • MPPT controller with dry-run protection
  • Remote monitoring system (RMS)
  • AC and DC options
  • Works on borewells and open wells
PriceIndicative ₹2,50,000–3,80,000 full system cost incl. GST before subsidy, depending on AC/DC, head and state; farmer share under PM-KUSUM varies by state; final price on quote.
SKU: SEMS-PMP-5HP
Genuine, warranty-backed Pan-India dispatch Installation available

Technical specifications

Pump rating5 HP (≈3.7 kW)
Pump typeSubmersible (borewell) or surface/monoblock
MotorAC induction with VFD, or DC BLDC/PMSM
Solar array≈4.8 kWp DCR, ALMM-listed modules
ControllerMPPT-based VFD/controller with dry-run, overload protection
Head range≈30–100 m (submersible), ≈10–25 m (surface)
Daily discharge≈70,000–1,50,000 litres (sunny day, head-dependent)
StructureGI with manual seasonal tilt or tracking option
Remote monitoringRMS (GSM-based) as per scheme norms
StandardsPer MNRE solar pump specifications; BIS-certified components
Quick answer: A 5 HP solar water pump uses about 4.8 kWp of DCR solar panels and an MPPT controller to lift roughly 70,000–1,50,000 litres a day, depending on head. It removes diesel and power costs for irrigation. Under PM-KUSUM Component B, central and state assistance typically covers about 60% of the cost, though shares vary by state.

Who is it for?

Farmers with borewells or open wells irrigating roughly 3–8 acres, farmers currently using diesel pumps or facing unreliable night-time feeder supply, and FPOs, orchards, nurseries and dairy farms. Read our PM-KUSUM guide.

Key benefits

  • No fuel cost: a diesel pump can burn several litres an hour.
  • Daytime irrigation without depending on feeder schedules.
  • Low maintenance: no engine oil or fuel logistics.
  • Subsidy support under PM-KUSUM (extended to March 2027).

Technical specifications

Specification Typical value
Pump rating 5 HP (≈3.7 kW)
Pump type Submersible (borewell) or surface/monoblock
Motor AC induction with VFD, or DC BLDC/PMSM
Solar array ≈4.8 kWp DCR, ALMM-listed modules
Controller MPPT-based VFD/controller with dry-run, overload protection
Head range ≈30–100 m (submersible), ≈10–25 m (surface)
Daily discharge ≈70,000–1,50,000 litres (sunny day, head-dependent)
Structure GI with manual seasonal tilt or tracking option
Remote monitoring RMS (GSM-based) as per scheme norms
Standards Per MNRE solar pump specifications; BIS-certified components

Installation & warranty

We check borewell depth, water level, yield and delivery distance to choose the right head and pump. Use the solar pump calculator for a first estimate. The array is mounted near the well with fencing recommended. Scheme pumps usually carry a 5-year comprehensive maintenance contract, and modules a 25-year performance warranty.

Key takeaways

  • 5 HP pump with ~4.8 kWp DCR array
  • ≈70,000–1,50,000 litres/day, head-dependent
  • PM-KUSUM: about 60% assistance, varies by state
  • Choose head and pump type after a well survey

Switch from diesel to sunshine. get a free quote for a solar pump sized to your well.

Frequently asked questions

How much water does a 5 HP solar pump give?

Roughly 70,000–1,50,000 litres a day on a sunny day, depending on total head (depth plus delivery height), pump type and season.

How much does a farmer pay under PM-KUSUM?

Under Component B, typically 30% central and 30% state assistance, leaving about 40% for the farmer, of which a bank loan can cover up to 30%. Several states give higher support. Check your state's nodal agency and pmkusum.mnre.gov.in.

AC or DC pump: which is better?

DC (BLDC/PMSM) pumps are more efficient and work at lower light levels; AC pumps with a VFD are easier to repair locally. Both are available under PM-KUSUM.

Can the pump run on cloudy days?

Output drops in cloudy weather. Pumping usually starts at moderate sunlight and peaks between 10 am and 3 pm. There is no battery in a standard solar pump.

You may also need

HomeBusiness

ACDB, DCDB & Lightning Arrester / Earthing Kit

Protection and safety balance-of-system for solar plants: AC and DC distribution boxes, surge protection, lightning arresters and earthing.

Indicative ₹6,000–20,000 per set for residential systems, ex-GST; C&I boxes on request; final price…

HomeBusiness

Solar Water Heater 100–300 LPD

Evacuated-tube (ETC) solar water heaters that provide hot water at 50–60°C for homes, hostels, hotels and hospitals.

Indicative ₹18,000–45,000 for 100–300 LPD ETC systems, ex-GST (5% GST applies); installation and plumbing…

सूर्य की शक्ति, भारत की प्रगति

Need a complete system, not just a product?

Our engineers will design a matched system — panels, inverter, battery, structure and protection — and install it end-to-end.